Darbo laikas: I-V 10:00 - 16:30
Kaunas

Kategorijos

Reikia pagalbos?

Nerandate ieškomos prekės? Ar reikia konsultacijos?

Susisiekite su mumis: [email protected] arba
+370 609 37005

A0009053503 5WK96682C NOX Daviklis

  • Kaina: 299.95€
  • Turime sandėlyje  
  • Gausite: 1 NOX daviklį
  • Būklė: Naujas
  • Continental detalės kopija
  • Mercedes Benz detalės kodas: A0009053503 
  • Continental detalės kodas: 5WK96682C 
  • Garantija: 1 metai
  • Galime sutaisyti seną daviklį, klauskite
APRAŠYMAS

Mercedes Benz A0009053503 5WK96682C NOX Daviklis.

Daviklis pakeičia continental detale mercedes benz automobiliuose su AdBlue sistema.

Jei užsidegė įspėjimas jog reikia patikrinti variklio darbinius parametrus klaida ir po diagnostikos jums rodo šiuos klaidos kodus P229F62 bank 1 ir arba P2202 bank 2, tuomet jums reikės pakeisti adblue sistemos NOX daviklius.

Padaryti diagniostika, kad nustatytume šias klaidas jums nereikia nuvykti į oficialia Mercedes-Benz atstovybę, tai galite padaryti patys su papraščiausiu OBD2 skeneriu.

NOX reiškia azoto oksidai.

Po A0009053503 NOX daviklio pakeitimo, gali reikėti padaryti detalės adaptacija ir nunulinti skaičiavimo reikšmes.

5WK96682C daviklis naudojamas BlueTec ir 4Motion 4-Motion modeliuose.

Dazniausiai pasitaikancios mercedes-benz klaidos

  • AdBlue malfunction em. op. in x mi km see owner's man.
  • AdBlue system malfunction See Owner's Man.
  • AdBlue system malfunction Emergency modie in x mls km
  • Cannot measure fluid level AdBlue
  • Eng. Start not possible in x mi km
  • Engine start not possible in x mi km
  • Cannot measure fluid level AdBlue

Dazniausiai pasitaikancios diagnostikos klaidos

  • U029E00 Lost communication with NOX sensor B
  • U029E Lost communication with NOX sensor B
  • P229F62 NOx sensor 2 (cylinder bank 1) has a malfunction. The signal comparision is faulty
  • P13DF09 The AdBlue system has a malfunction. There is a component fault
  • P229F62 The signal of component NOx sensor is implausible. The following test procedure must always be performed in its entirety
  • P220162 The signal of component NOx sensor is implausible. The following test procedure must always be performed in its entirety
  • P229F-91 P229F91 NOx sensor 2 (cylinder bank 1 ) Has a malfunction, the parameter is outside the permissible range
  • P220F NOx sensor heater control circuit range / performance bank 1 sensor 2
  • P229E NOx sensor Circuit bank 1 sensor 2
  • P229F NOx sensor circuit range / performance bank 1 sensor 2
  • P220F77 - NOx sensor heating (Bank 1 sensor 2) Specified position not reached
  • P220F77 - The heater of NOx sensor 2 (cylinder bank 1) has an electrical fault. The commanded position cannot be reached
  • 111B00 The upper limit value of component NOx sensor downstream of SCR catalytic converter has been exceeded
  • P229F92 NOx sensor 2 (cylinder bank 1) has a malfunction.The function or the instruction is faulty
  • U029D87 Communication with NOx sensor 1 has a malfunction. The message is missing
  • 178700 The upper limit value of component NOx sensor upstream of SCR catalytic converter has been exceeded
  • P13E400 The remaining driving distance is limited due to a malfunction in the adblue system
  • P229E11 NOx sensor 2 (cylinder bank 1) has a an electrical fault. Circuit short to groudn
  • P2BA9FD The emission limit for the NOx concectration has been exceeded (AdBlue quality is too low)
  • P13F600 The engine cannot be started because the exhaust aftertreatment system has been tampered with
  • P229F09 NOx sensor 2 (cylinder bank 1) has a malfunction. There is a component fault
  • 14B500 A plausibility error exists in the component Nitrogen Oxide (NOx) sensor upstream of the selective catalytic reduction (SCR) catalytic converter
  • 153500 Component Nitrogen Oxide (NOx) sensor upstream of the selective catalytic reduction (SCR) catalytic converter responds too slowly
  • 133000 The upper limit value of component Nitrogen Oxide (NOx) sensor upstream of the selective catalytic reduction (SCR) catalytic converter has been attained
  • P1BC300 Additional fault freeze frame data for fault analysis (Data set 03)
  • P229FFF Nitrogen Oxide (NOx) sensor 2 (cylinder bank 1) is faulty
  • P220011 An electrical fault exists in the NOx sensor (cylinder bank 1). There is a short circuit to ground
  • P220E77 The heater of NOx sensor 1 (cylinder bank 1) is faulty. The commanded position cannot be achieved
  • P220F77 P220F-77 NOx sensor heater control circuit range / performance bank 1 sensor 2. The commanded position cannot be reached
  • P2201FC P2201-FC The NOx sensor (cylinder bank 1) has a malfunction

Mercedes-Benz detalės kodai:

  • A 000 905 35 03
  • A 0009053503
  • A0009053503 

Continental detalės kodai:

  • 5WK96682C 
  • 5WK9 6682C 

Mercedes-Benz automobiliai, kurie naudoja daviklį:

  • Sprinter W906
  • 109 CDI 111 CDI 114 CDI 116 CDI 119 BlueTec
  • Vito W447 Bus 2014 2015 2016 2017 2018
  • V200 V220 V250 
  • S klase W222
  • S300d S320d S350d BlueTEC dizelinas
  • SLK klase R172
  • C klase W205 Sedanas W205 2015 2016 2017 2018
  • C220d BlueTEC 2.1 diesel C250d
  • C220 Blue TEC 2.1 diesel 4MATIC
  • C klase S205 C220d Wagon Estate
  • E klase C207 Kupe 2010 2011 2012 2013 2014 2015
  • E klase A207 Kabrioletas 2010 2011 2012 2013 2014 2015
  • 2.0L CDI E220d E250d diesel
  • GL X164 GL350 Bluetec
  • ML W164 Facelift SUV
  • ML250 ML350 BlueTEC diesel 4MATIC
  • GLA X156 GLA350d 2014 - 2017
ATSILIEPIMAI
Pastaba: Įvestas tekstas nebus išverstas.
    Blogas           Geras